RRC Connection Setup Complete is missing, the UE cannot attach.
Possible reasons:
·
Weak RSRP/RSRQ → Low signal strength.
·
Interference → Neighbouring cell interference.
·
Congestion → Too many users causing RRC setup failure.
Debugging in QXDM
- Check 0xB889 (Serving
Cell RSRP/RSRQ) to confirm signal quality.
- Look at 0xB883 (RRC Connection Setup Failure)
logs for failure reasons.